Item Description
The 1/2'''' 975XL2TCU Reduced Pressure Principle Backflow Assembly is used in high hazard, potable water applications for protection against both backsiphonage and backpressure of contaminated water into the potable water supply. The wye pattern, bronze body test cocks are oriented face up and positioned vertically for easy installation close to a wall. The convenient separate access to the relief valve and each check valve reduces labor costs and repair time. The 975XL2TCU is favored by installers around the world, and is the simplest, best performing, and most reliable backflow preventer in the irrigation market today.
Item ID: 407AEX1
Width:
Height:
Extra Data: Entire unit serviceable in-line for high efficiency, Low-lead law compliant, Test cocks pointed up for easy installation close to a wall, Wye pattern design reduces installation time and costs
Family: xl2
Bullet10: Certified to NSF/ANSI 372* by IAPMO R&T
Bullet5: ASSE® Listed 1013
Bullet6: IAPMO® Listed
Bullet7: CSA® Certified
Bullet8: AWWA Compliant C511
Bullet9: Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California
Country: USA
Description: The 1/2'' 975XL2TCU Reduced Pressure Principle Backflow Assembly is used in high hazard, potable water applications for protection against both backsiphonage and backpressure of contaminated water into the potable water supply. The wye pattern, bro
Extra Data: Entire unit serviceable in-line for high efficiency, Low-lead law compliant, Test cocks pointed up for easy installation close to a wall, Wye pattern design reduces installation time and costs
Family: xl2
Bullet10: Certified to NSF/ANSI 372* by IAPMO R&T
Bullet5: ASSE Listed 1013
Bullet6: IAPMO Listed
Bullet7: CSA Certified
Bullet8: AWWA Compliant C511
Bullet9: Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California
Description: The 1-1/4'' 975XL2TCU Reduced Pressure Principle Backflow Assembly is used in high hazard, potable water applications for protection against both backsiphonage and backpressure of contaminated water into the potable water supply. The wye pattern, b
Extra Data: Entire unit serviceable in-line for high efficiency, Low-lead law compliant, Test cocks pointed up for easy installation close to a wall, Wye pattern design reduces installation time and costs
Family: xl2
Bullet10: Certified to NSF/ANSI 372* by IAPMO R&T
Bullet5: ASSE Listed 1013
Bullet6: IAPMO Listed
Bullet7: CSA Certified
Bullet8: AWWA Compliant C511
Bullet9: Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California
Description: The 1-1/2'' 975XL2TCU Reduced Pressure Principle Backflow Assembly is used in high hazard, potable water applications for protection against both backsiphonage and backpressure of contaminated water into the potable water supply. The wye pattern, b
Extra Data: All bronze body with corrosion resistant internals, Low-lead law compliant, Replaceable check and relief valve seats, Top access checks for easy repair in tight locations
Item Description
Our most popular backflow preventer model, the 3/4'''' 975XL2FT Reduced Pressure Principle Backflow Preventer comes with integral male 45° flare SAE test fitting. It is utilized on potable water applications for high health hazard protection from backsiphonage and backpressure of contaminated water. The wye pattern, bronze body design provides separate access to each check valve and the relief valve to reduce valuable labor costs and repair time, while the short lay length eases replacement costs. The 975XL2 includes all the necessary components for managing your system, and is the simplest, most reliable backflow preventer in the irrigation market today.
Item ID: 40749JC
Width:
Height:
Extra Data: Easy access to first check simplifies debris removal, Entire unit serviceable in line, Pre-assembled with backflow, pressure regulation, and strainer components, Repair kit allows for a quick fix, instead of a full replacement
Family: xl2
Bullet10: Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California
Bullet5: Low-lead law compliant
Bullet6: ASSE® Listed 1013
Bullet7: IAPMO® Listed
Bullet8: CSA® Certified B64.4
Bullet9: AWWA Compliant C511
Country: USA
Description: The Zurn Wilkins 975XL2 Reduced Pressure Principle Backflow Preventer provides high hazard protection for potable water applications. The wye pattern, bronze body offers separate access to each check valve and the relief valve for servicing.
Extra Data: 300 series stainless steel springs resist corrosion, Domestic and commercial installation options add versatility, Maximum working water pressure of 400 WOG, Prevention of discharge due to fluctuations in inlet pressure and water hammer
Family: xl2
Bullet5: UL Classified
Bullet6: Lead-free
Country: Italy
Description: The 1-1/4'' 40XL2 In-Line Single Check Valve is utilized on potable water applications in both domestic and commercial water systems, including well pump systems and applications where tight seating is required. It is frequently used to prevent dis
Height: 3.6
Length: 2.9
Line: 480
Low Lead: Yes
Prop65: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Item Description
Our most popular backflow preventer model, the 1-1/2'''' 975XL2S Reduced Pressure Principle Backflow Preventer with bronze wye type strainer is utilized on potable water applications for high health hazard protection from backsiphonage and backpressure of contaminated water. The wye pattern, bronze body design provides separate access to each check valve and the relief valve to reduce valuable labor costs and repair time, while the short lay length eases replacement costs. The 975XL2 includes all the necessary components for managing your system, and is the simplest, most reliable backflow preventer in the irrigation market today.
Item ID: 406V4JX
Width:
Height:
Extra Data: Easy access to first check simplifies debris removal, Entire unit serviceable in line, Pre-assembled with backflow, pressure regulation, and strainer components, Repair kit allows for a quick fix, instead of a full replacement
Family: xl2
Bullet10: Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California
Bullet5: Low-lead law compliant
Bullet6: ASSE® Listed 1013
Bullet7: IAPMO® Listed
Bullet8: CSA® Certified B64.4
Bullet9: AWWA Compliant C511
Country: USA
Description: The Zurn Wilkins 975XL2 Reduced Pressure Principle Backflow Preventer provides high hazard protection for potable water applications. The wye pattern, bronze body provides separate access to each check valve and the relief valve for servicing.
Item Description
The 3/4'''' 975XL2TCUFT Reduced Pressure Principle Backflow Assembly with integral male 45° flare SAE test fitting is used in high hazard, potable water applications for protection against both backsiphonage and backpressure of contaminated water into the potable water supply. The wye pattern, bronze body test cocks are oriented face up and positioned vertically for easy installation close to a wall. The convenient separate access to the relief valve and each check valve reduces labor costs and repair time. The 975XL2TCU is favored by installers around the world, and is the simplest, best performing, and most reliable backflow preventer in the market today.
Item ID: 407HG7Z
Width:
Height:
Extra Data: Entire unit serviceable in-line for high efficiency, Low-lead law compliant, Test cocks pointed up for easy installation close to a wall, Wye pattern design reduces installation time and costs
Family: xl2
AltImageName1: /ZRN/ZRN112-975LXL2_1.jpg
AltImageName2: /ZRN/ZRN112-975LXL2_2.jpg
AltImageName3: /ZRN/ZRN112-975LXL2_3.jpg
AltImagePath1: /ZRN-ZRN112-975LXL2_1.JPEG
AltImagePath2: /ZRN-ZRN112-975LXL2_2.JPEG
AltImagePath3: /ZRN-ZRN112-975LXL2_3.JPEG
Bullet10: Certified to NSF/ANSI 372* by IAPMO R&T
Bullet5: ASSE® Listed 1013
Bullet6: IAPMO® Listed
Bullet7: CSA® Certified
Bullet8: AWWA Compliant C511
Bullet9: Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California
Country: USA
Description: The Zurn Wilkins 975XL2TCU Reduced Pressure Principle Backflow Preventer provides high hazard protection for potable water applications. The wye pattern, bronze body test cocks oriented in the vertical position, facing up.
Item Description
The 1-1/2'''' 975XL2 Reduced Pressure Principle Assembly with bronze wye type strainer and an air gap is used in high health hazard, potable water applications for protection from both backsiphonage and backpressure of contaminated water into the potable water supply. The wye pattern, bronze body design provides separate access to each check valve and the relief valve to reduce labor costs and repair time. Its short lay length eases replacement costs and installation time. The 975XL2 includes all the necessary components for managing your system, and is the simplest, best, and most reliable backflow preventer in the market today.
Item ID: 406V4JY
Width:
Height:
Extra Data: Low-lead law compliant, Short lay length eases replacement and repair time, Trusted and recognized favorite by installers worldwide, Wye pattern design provides separate access to checks and relief valve for reduced labor costs
Family: xl2
AltImageName1: /ZRN/ZRN112-975LXL2_1.jpg
AltImageName2: /ZRN/ZRN112-975LXL2_2.jpg
AltImageName3: /ZRN/ZRN112-975LXL2_3.jpg
AltImagePath1: /ZRN-ZRN112-975LXL2_1.JPEG
AltImagePath2: /ZRN-ZRN112-975LXL2_2.JPEG
AltImagePath3: /ZRN-ZRN112-975LXL2_3.JPEG
Bullet10: Meets the requirements of NSF/ANSI 61
Bullet5: ASSE® Listed 1013
Bullet6: IAPMO® Listed
Bullet7: CSA® Certified B64.4
Bullet8: AWWA Compliant C511
Bullet9: Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California
Country: USA
Description: The Zurn Wilkins 1-1/2'' 975XL2 Reduced Pressure Principle Backflow Preventer provides high hazard protection for non-potable water applications. The wye pattern, bronze body provides separate access to each check valve and the relief valve for ser